Alcolizer Melcorp Wall Mounted Breathalyser

Miscellaneous
$6,282.24
Secure checkout
VISA Mastercard Apple Pay Google Pay
In stock
Only 1000 left
SKU
400037

The Alcolizer Melcorp wall mounted breathalyser is a fixed, self-service breath alcohol tester built for Australian workplaces: mine sites, transport depots, construction, manufacturing and licensed venues. It was the first Australian Standards Certified (AS 3547 Type III) wall mount unit, and it recalibrates itself every 24 hours from an internal NATA certified reference gas.

Why a wall mounted breathalyser rather than a hand held

A hand held unit needs someone to operate it. A wall mounted breathalyser sits at the entry point and lets people test themselves, unsupervised, every time they come on site. That changes what the testing is for: instead of a supervisor selecting who gets tested, everyone tests, and the awkward conversation happens before someone starts work rather than after an incident.

If you need a portable unit for field or random testing instead, the Alcolizer HH1 hand held is the same platform in a portable form.

The self-calibration is the point

Breath testing instruments drift, and a unit that has drifted is worse than no unit because people trust the number. Most instruments handle this by being sent away periodically for calibration, which means downtime, a swap unit, and a schedule someone has to own.

This one carries its own NATA certified reference gas internally and recalibrates every 24 hours without intervention. There is no manual calibration to schedule and no unit to send away. Over a multi-year deployment that is usually the difference in running cost, not the purchase price.

Accuracy and how it measures

It uses high grade platinum electrochemical fuel cell technology, the same sensing method used in police devices internationally. Fuel cell sensors respond to ethanol specifically, which is why they are preferred over cheaper semiconductor sensors that can react to other substances on the breath. Combined with evidential style test operation, that is what AS 3547 Type III certification reflects.

Running it day to day

  • Consumables are standard drinking straws as single use mouthpieces, so ongoing cost is negligible and you are not locked to a proprietary part.
  • Three programmable BAC set point alarm levels, available as three relay outputs, so it can drive a gate, a light or a siren.
  • Data logging with serial interface connectivity for download to external devices.
  • Programmable scrolling LED display.
  • Robust steel case, built for industrial environments.
Set points, data download and display options are configured per site. Contact Alcolizer or your distributor for configuration, long term data storage and backup.

Specifications

TypeWall mounted, self-service breath alcohol tester
CertificationAS 3547 Type III, first certified wall mount unit
SensorHigh grade platinum electrochemical fuel cell
CalibrationAutomatic every 24 hours, internal NATA certified gas
Test modeEvidential style
AlarmsThree programmable BAC set points, three relay outputs
DataData logging, serial interface to external devices
MouthpiecesStandard drinking straws, single use
CaseSteel

See the wider medical supplies range for workplace testing consumables.

Alcolizer wall mounted breathalyser FAQs

What is the Alcolizer wall mounted breathalyser used for?

Fixed, self-service breath alcohol testing at workplace entry points: mine sites, transport and logistics depots, construction sites, manufacturing plants and licensed venues, wherever regular unsupervised BAC testing is required.

Is it certified to Australian Standards?

Yes, to AS 3547 Type III. It was the first Australian Standards Certified wall mount unit, using evidential style test operation and high grade platinum electrochemical fuel cell technology.

How often does it need calibration?

It recalibrates itself every 24 hours from its own internal NATA certified reference gas. No manual or external calibration is needed for day to day operation, and there is no swap unit to arrange.

What consumables does it use?

Standard drinking straws as single use mouthpieces, which keeps running cost and maintenance low and avoids a proprietary consumable. Budget for straws and nothing else in normal operation.

How is it different from the hand held Alcolizer?

The hand held HH1 is portable and operated by a person, suiting random and field testing. The wall mount is fixed at an entry point and used unsupervised by staff themselves. Many sites run both, using the wall unit for routine self-testing and a hand held for supervised or follow up tests.

Can it control a gate or alarm?

Yes. It has three programmable BAC set point alarm levels with three relay outputs, which can be wired to a gate, indicator light, siren or access control system. Configuration is site specific, so discuss your set points with your distributor.

Can we get the test data out of it?

It logs data and has a serial interface for download to external devices. For long term storage, backup and reporting arrangements, contact Alcolizer directly, since that depends on how your site wants records kept.