Lux Black Finger Pulse Oximeter
The Lux Black Finger Pulse Oximeter measures pulse oxygen saturation, pulse rate and perfusion index through the finger. What sets it apart from a basic oximeter is what it shows and how long it will run: an OLED display with a live pulse waveform and perfusion index, plus a continuous monitoring mode alongside spot checks, storage for up to 12 groups of SpO2 data, and audible and visual alarms. Suitable for adult and paediatric patients in clinics, hospitals and at home.
Key Features
- OLED display of SpO2, pulse rate, perfusion index, pulse bar and waveform
- Spot check AND continuous measurement modes
- Audio and visual alarms, with low-battery indication
- Stores up to 12 groups of SpO2 data
- Pulse rate analysis on spot-check measurements
- Artefact removal and anti-motion processing for a stable reading
- Splash and drop resistant, multi-direction display, automatic power on/off
Specifications
| Measures | SpO2, pulse rate, perfusion index |
| Display | OLED with waveform |
| Modes | Spot check and continuous |
| Alarms | Audio and visual |
| Memory | 12 groups |
| Patients | Adult and paediatric |
| SKU | ASPOX1 |
Uses
Clinics, hospitals, aged care and home monitoring of oxygen saturation. For a simpler spot-check unit see the ChoiceMMed finger oximeter. Browse the Aero Healthcare range.
Pulse Oximeter FAQs
What is the perfusion index for?
It indicates how strong the blood flow is at the sensor site. A very low perfusion index warns you the SpO2 reading may be unreliable — useful, because a basic oximeter will show you a confident-looking number with no such caveat.
Why does the waveform matter?
The waveform shows whether the device is picking up a clean pulse. A ragged or absent trace tells you the reading is an artefact of movement or poor placement rather than a real measurement.
Spot check or continuous mode?
Spot check for a single reading during an assessment. Continuous mode is for watching a patient over time — paired with the alarms, that is what makes it usable for monitoring rather than just measuring.
What affects accuracy?
Cold fingers, poor circulation, nail polish, artificial nails and movement all degrade the reading. Warm the hand, remove polish and keep still. Any oximeter reading is one input to a clinical assessment, not a diagnosis.
You must not rely on the information on this site as an alternative to medical advice from your medical physician or other qualified healthcare provider. Consult your healthcare provider immediately if you think that you may have a medical emergency or for the diagnosis and treatment of injuries. Always seek the advice of your physician or other qualified healthcare provider before starting any new treatment or with any questions that you may have regarding a medical condition or injury.